Menu
Menu
Your Cart

Neonatal and Pedi. Clamp cvd deli. Fig.1 14cm

Neonatal and Pedi. Clamp cvd deli. Fig.1 14cm
Neonatal and Pedi. Clamp cvd deli. Fig.1 14cm
$64.99
  • Stock: In Stock
  • Brand: Hilbro
  • Model: 34.0634.01
  • SKU: HILB-CLAMP-GENR-SS-114-05176

Clinical Application

Designed for neonatal and pediatric surgical environments, this curved, delicate clamp provides controlled, atraumatic occlusion of small vessels and delicate soft tissues. Its small profile and fine jaws are suitable for procedures in the delivery room, neonatal intensive care unit (NICU) and pediatric operating room where precision and minimal tissue trauma are required—examples include umbilical vessel control, small-vessel hemostasis, tissue approximation and temporary fixation during reconstructive or general pediatric procedures.

Design & Configuration

The curved geometry improves access and visibility around anatomic structures in confined operative fields common to neonatal and pediatric cases. A delicate jaw profile reduces crushing injury to fragile tissues while allowing a secure hold. At 14 cm overall length the instrument balances reach and maneuverability—long enough to access deeper small cavities yet short enough for precise fingertip control. The Figure 1 pattern indicates a compact, low-profile tip optimized for fine work.

Instrument Specifications

  • Instrument type: neonatal/pediatric clamp
  • Pattern / model: Fig. 1
  • Configuration: curved, delicate profile
  • Length: 14 cm
  • Tip / jaw pattern: fine, atraumatic jaws for small vessels and soft tissue
  • Typical surgical use: temporary occlusion and atraumatic grasping in neonatal and pediatric procedures
  • Material: surgical-grade stainless steel
  • Reusable: yes

Material & Construction

Constructed from surgical-grade stainless steel to withstand repeated sterilization cycles and provide corrosion resistance. Precision manufacturing of the jaws and hinge ensures consistent alignment and secure engagement when applying atraumatic pressure to small vessels and tissues. The instrument is intended for reuse and compatible with standard hospital sterilization processes.

Quality & Compliance

Manufactured by FDA-registered OEM facilities and produced under strict quality control standards.

Brand Comparison

Comparable in form and function to equivalent instruments offered by major US medical suppliers.

Availability & Returns

  • In-stock lead time: ships within ~1 week
  • Out-of-stock lead time: 2–4 weeks
  • Returns: 30-day return policy

Write a review

Note: HTML is not translated!
Rating
Bad Good
Captcha