Model: 14.0344.22
Clinical Application
Right-angle hemostatic forceps used to achieve hemostasis and to facilitate ligation or suture delivery around structures that are difficult to access in a straight line. Commonly employed in thoracic procedures for control of bronchial branches and pulmonary vessels, in mediast..
$59.99
Model: 14.0441.22
Clinical Application
Right-angle hemostatic forceps are used to reach around structures and control bleeding in confined or deep operative fields. Common applications include isolating and clamping vessels, passing ties or drains behind vascular or tubular structures, blunt dissection along tissue p..
$59.99
Model: 14.0441.25
Clinical Application
Right-angle hemostatic forceps are used to control bleeding, pass ligatures, and perform blunt dissection around vessels and tubular structures where a straight instrument cannot access easily. The 25 cm length provides extended reach for deep abdominal, retroperitoneal, pelvic,..
$59.99
Model: 14.0441.28
Clinical Application
Right-angled hemostatic forceps with a 90-degree bend are used to gain controlled vascular access and perform blunt dissection in confined or deep operative fields. This configuration facilitates placement of clamps around vessels, ducts, or tissue pedicles when a straight instr..
$49.99
Model: 14.0430.15
Clinical Application
Right-angle forceps are used to reach around and behind structures in confined operative fields where a straight instrument cannot access safely. This pattern is routinely employed to pass ligatures or vessel loops around vascular pedicles, to retrieve or position drains and tub..
$49.99
Model: 14.0430.19
Clinical Application
Right-angle forceps provide controlled access to vessels, pedicles and tissues that lie deep or around structures where a straight instrument cannot reach. This curved Mixter/O'Shaughnessy pattern is used to pass suture or vessel loops behind arteries, veins and ductal structure..
$59.99
Model: 10.0101.15
Clinical Application
Right-angle Mixter scissors with a curved, blunt/blunt tip are used to dissect, isolate, and divide tissue around vessels and tubular structures in confined or deep operative fields. The right-angle tip permits controlled lateral dissection and the creation of a window under ves..
$39.73
Model: 10.5101.15
Clinical Application
Mixter scissors with blunt/blunt tips, curved configuration, 15.5 cm length and tungsten carbide inserts. Offers a curved cutting profile for controlled tissue dissection and manipulation in surgical settings where a blunt tip is preferred.
Design & Configuration
Curved geom..
$109.99
Model: 10.0100.15
Clinical Application
Mixter scissors are used to dissect tissue planes and to pass sutures, ligatures or vessel loops around tubular structures in confined or deep operative fields. The blunt/blunt tip configuration minimizes inadvertent cutting during blunt dissection and when creating a safe tunne..
$39.78
Model: 10.5100.15
Clinical Application
Straight Mixter scissors with blunt/blunt tips and tungsten carbide inserts. Designed to provide a reliable straight cutting instrument where blunt tips are preferred.
Design & Configuration
Straight scissors geometry
Blunt/blunt tip and jaw pattern
Length: 15.5 cm
Equ..
$109.99
Model: 16.0051.17
Clinical Application
Curved Martin-style dressing forceps are intended for secure handling of dressings, sponges, sutures, and small tissue fragments during wound care and perioperative procedures. The 17 cm length gives clinicians a balance of reach and control for bedside dressing changes, minor s..
$49.99
Model: 16.0050.17
Clinical Application
Modified Martin dressing forceps, straight, 17 cm, are intended for secure handling and manipulation of dressings, sponges, packing material and other non-delicate items during operative procedures and post-operative wound care. Their length and straight alignment provide contro..
$49.99